To make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more.
Other useful capabilities:
Electrical Specifications | |
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (48 – 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 @ 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0 % ± 5 digits (48 – 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1 % ± 5 digits |
Resistance | |
Range | 600.0 Ω/6000 Ω |
Resolution | 0.1 Ω/1 Ω |
Accuracy | 1 % ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 – 100.0 μF / 1000 μF |
Resolution | 0.1 μF/1 μF |
Accuracy | 1.9 % ± 2 digits |
Mechanical Specifications | |
Size (L x W x H) | 232 mm x 85 mm x 45 mm |
Weight | 370 g |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temp | -40 °C to +60 °C |
Operating Humidity | Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
Agency Approvals | |
Batteries | 2 AA, NEDA 15A, IEC LR6 |