• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    PCE Instruments CM 5 Current Clamp Meter AC 0 to 200 AC

    # CM 5

    • The digital multimeter is a multimeter with a multitude of different functions. Thus, with the digital multimeter, current measurements up to 200 A AC can be carried out without contact.
    • Thanks to the contactless current measurements of the digital multimeter can be measured during operation. Thus, no measurement preparation must be made with the digital multimeter, since it is possible to measure directly on the line to be measured.
    • Another contactless feature of the digital multimeter is the NCV (Not Connected Voltage) measurement. In this measurement, the digital multimeter can indicate whether a voltage is applied to a line.
    • The digital multimeter is a multimeter with a multitude of different functions. Thus, with the digital multimeter, current measurements up to 200 A AC can be carried out without contact. This current range of the digital multimeter already covers a large range of current measurements. Thanks to the contactless current measurements of the digital multimeter can be measured during operation. Thus, no measurement preparation must be made with the digital multimeter, since it is possible to measure directly on the line to be measured.
    • Another contactless feature of the digital multimeter is the NCV (Not Connected Voltage) measurement. In this measurement, the digital multimeter can indicate whether a voltage is applied to a line. Again, no measurement preparation must be carried out during operation with the digital multimeter. These two features of the digital multimeter reduce the risk of injury from electric shock.
    • Other useful functions of the ammeter are the measurement of the resistance and the continuity test. With the continuity check of the digital multimeter, it can be determined, for example, whether a relay in a switch box is completely closed. Thanks to the fast measuring frequency of the digital multimeter, possible power fluctuations can be determined. This makes the digital multimeter an indispensable tool for every electrician.
    • Inductive current measurement up to 200 A AC
    • Voltage measurement with frequency meter
    • “Hold” function for freezing the measured value
    • Temperature measurement with thermocouple
    • Small and compact design
    • Smaller internal resistance with the LowZ function
    Alternating current
    Measuring rangeResolutionAccuracy
    200 A0.1 A± (3.0% + 3 digits)
    Frequency range: 40 … 400 Hz
    Maximum input current: 200 A AC
    Direct current
    Measuring rangeResolutionAccuracy
    600 µA0.1 µA± (1.0% + 4 digits)
    1000 µA1 µA± (1.0% + 4 digits)
    Maximum input current: 1000 µA
    DC
    Measuring rangeResolutionAccuracy
    600 mV0.1 mV± (0.7% + 3 digits)
    6V0.001 V± (0.7% + 3 digits)
    60V0.01 V± (0.7% + 3 digits)
    600V0.1 V± (0.7% + 3 digits)
    Input impedance: 10 MΩ
    maximum input voltage: 600V DC AC rms
    AC
    Measuring rangeResolutionAccuracy
    6V0.001V± (0.8% + 3 digits)
    60V0.01V± (0.8% + 3 digits)
    600V0.1V± (0.8% + 3 digits)
    Input impedance: 10 MΩ
    Maximum input voltage: 600V DC AC rms
    Frequency range: 40 … 400 Hz
    LowZ AC / DC
    Measuring rangeResolutionAccuracy
    600V0.1V± (2.0% + 3 digits)
    Input impedance: 10 MΩ
    Maximum input voltage: 600V DC AC rmsS
    Frequency range: 40 … 400 Hz
    Resistance
    Measuring rangeResolutionAccuracy
    600 Ω0.1 Ω± (0.8% + 3 digits)
    6 kΩ0.001 kΩ± (0.8% + 3 digits)
    60 kΩ0.01 kΩ± (0.8% + 3 digits)
    600 kΩ0.1 kΩ± (0.8% + 3 digits)
    6 MΩ0.001 MΩ± (1.2% + 3 digits)
    60 MΩ0.1 MΩ± (1.2% + 3 digits)
    Test voltage (open circuit): 0.4V
    Surge protection: 250V AC / DC rms
    Continuity test
    Measuring rangeResolutionaccuracy
    0.1 Ω
    Surge protection: 250 V AC / DC rms
    Beep at <50 Ω
    Diode test
    Measuring rangeResolutionAccuracy
    0.001V
    Surge protection: 250V AC / DC rms
    Forward current: 1-mA DC
    Forward voltage: 3.3V DC
    Capacities
    Measuring rangeResolutionAccuracy
    99.99 nF0.01 nF± (4.0% + 5 digits)
    999.9 nF0.1 nF± (4.0% + 5 digits)
    9.999 µF0.001 µF± (4.0% + 5 digits)
    99.99 µF0.01 µF± (4.0% + 5 digits)
    999.9 µF0.1 µF± (4.0% + 5 digits)
    9.999 mF1 µF± (4.0% + 5 digits)
    99.99 mF0.01 mF± (4.0% + 5 digits)
    Surge protection: 250V AC / DC rms
    Temperature (thermocouple type K)
    Measuring rangeResolutionAccuracy
    -20 … 0°C1°C± (3.0% + 2 digits)
    1 … 400°C1°C± (2.0% + 2 digits)
    -4 … 32°F1°F± (3.0% + 4 digits)
    33 … 752°F1°F± (2.0% + 4 digits)
    Surge protection: 250V AC / DC rms
    Frequency (with current probe)
    Measuring rangeResolutionAccuracy
    99.99 Hz0.01 Hz± (1.5% + 5 digits)
    999.9 Hz0.1 Hz± (1.5% + 5 digits)
    > 1 kHz0.001 kHzfor reference only
    Frequency range: 10 Hz … 1 kHz
    Maximum input current: 200 A AC rms
    Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
    Frequency (when measuring voltage)
    Measuring rangeResolutionAccuracy
    99.99 Hz0.01 Hz± (1.5% + 5 digits)
    999.9 Hz0.1 Hz± (1.5% + 5 digits)
    9.999 Hz0.001 kHz± (1.5% + 5 digits)
    > 10 kHz0.01 kHzfor reference only
    Frequency range: 10 Hz … 10 kHz
    Frequency (direct measurement)
    Measuring rangeResolutionAccuracy
    99.99 Hz0.01 Hz± (0.3% + 5 digits)
    999.9 Hz0.1 Hz± (0.3% + 5 digits)
    9.999 Hz1 Hz± (0.3% + 5 digits)
    99.99 kHz0.01 kHz± (0.3% + 5 digits)
    999.9 kHz0.1 kHz± (0.3% + 5 digits)
    9.999 kHz1 kHz± (0.3% + 5 digits)
    99.99 MHz0.01 MHz± (0.3% + 5 digits)
    Measuring range: 10 Hz … 60 MHz
    Input impedance: 10 MΩ
    Input range:> 0.2V AC rms (the input voltage increases, the frequency also increases)
    Maximum input voltage: 250V AC rms
    Duty cycle
    Measuring rangeResolutionAccuracy
    5 … 95%0.1%± 0.3%
    More specifications
    Range selectionAutomatically and manually
    Maximum working height2000 m / 6561.7 ft
    DisplayLCD display
    Largest display value5999
    Overrange“OL” display
    Measuring range underflow“-OL” display
    Measuring rate3 measurements per second
    Automatic shutdownAfter 15 minutes of inactivity
    Power supply1 x 9V block battery
    Operating conditions0 … 40°C / 32 … 104°F
    Storage conditions-10 … 50°C / 14 … 122°F
    Dimensions201 x 65 x 43 mm / 7.9 x 2.6 x 1.7 in
    WeightApprox. 265 g / < 1 lb (with battery)
    • 1 x Voltmeter PCE-CM 5
    • 1 x Pair of test leads
    • 1 x Transport bag
    • 1 x 9V Bock battery
    • 1 x User manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form