Features

  • The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current.
  • The current clamp may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.
  • Current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
  • Frequency range: DC to 100 kHz (-0.5 dB)
  • CAT III 300 V safety rating

Technical Information

  • Specified current range 30 mA to 30 A DC, 30 mA to 20 A AC rms
  • Usable current range 5 mA to 30 A DC, 30 mA to 20 A AC rms
  • Crest factor 1.4 in
  • Output sensitivity 100 mV/A
  • Accuracy (at +25°C) ±1% of reading ±2 mA
  • Resolution ±1 mA
  • Load impedance > 100 kΩ
  • Conductor position sensitivity ±1% relative to center reading
  • Frequency range DC to 100 kHz (-0.5 dB)
  • Operating temperature range 0°C to +50°C
  • Storage temperature range (with battery removed) -20°C to +85°C
  • Operating humidity 15% to 85% (non-condensing)

Downloads